CVE-2026-91007

HIGH
Published Nov 12, 2026 Modified Nov 12, 2026 CWE-822

Description

The user-mode syscall verifiers for the charger driver API in drivers/charger/charger_handlers.c did not inspect the prop argument before copying union charger_propval across the user/kernel boundary. Two members of that union are function pointers — status_notification (CHARGER_PROP_STATUS_NOTIFICATION) and online_notification (CHARGER_PROP_ONLINE_NOTIFICATION), declared in include/zephyr/drivers/charger.h — and z_vrfy_charger_set_prop() forwarded the caller-supplied union verbatim to the driver's set_property callback for any property. z_vrfy_charger_get_prop() had the mirror defect and copied the stored kernel callback address back out to user memory. With CONFIG_USERSPACE enabled, any user-mode thread that has been granted a charger device object could call charger_set_prop() with CHARGER_PROP_STATUS_NOTIFICATION or CHARGER_PROP_ONLINE_NOTIFICATION and an arbitrary pointer value. Drivers that implement these properties — drivers/charger/charger_max20335.c, drivers/charger/charger_pf1550.c and drivers/charger/charger_bq2518x.c — store the pointer in device data and later invoke it from their interrupt work handlers, which run in supervisor mode, on any charger state change such as a cable plug/unplug. The result is a control-flow hijack at kernel privilege from an unprivileged thread, defeating the isolation that CONFIG_USERSPACE is meant to provide; the read path additionally disclosed a kernel code address to user mode, and clearing a notifier installed by a supervisor thread let user mode suppress charger notifications. Supervisor-mode callers of charger_set_prop()/charger_get_prop() are unaffected. The fix makes both verifiers reject the two notifier properties outright — including when the supplied callback is NULL, since the notifiers are device state — and adds a BUILD_ASSERT on CHARGER_PROP_COMMON_COUNT so that new properties force a re-review of the union's user-mode safety.

Is your site exposed to CVE-2026-91007?

Run a free security scan — no signup, results in seconds.

CVSS v3.1 Score

7.8
HIGH
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

EPSS — Exploit Prediction

0.0011
Probability of exploitation
0.01%
Percentile rank

EPSS estimates the probability that this vulnerability will be exploited in the wild within the next 30 days. A higher score means more likely to be exploited.

Weakness Type (CWE)

CWE-822 CWE-822

References

Frequently Asked Questions

What is CVE-2026-91007? +
The user-mode syscall verifiers for the charger driver API in drivers/charger/charger_handlers.c did not inspect the prop argument before copying union charger_propval across the user/kernel boundary. Two members of that union are function pointers — status_notification (CHARGER_PROP_STATUS_NOTIFICATION) and online_notification (CHARGER_PROP_ONLINE_NOTIFICATION), declared in include/zephyr/drivers/charger.h — and z_vrfy_charger_set_prop() forwarded the caller-supplied union verbatim to the driver's set_property callback for any property. z_vrfy_charger_get_prop() had the mirror defect and copied the stored kernel callback address back out to user memory. With CONFIG_USERSPACE enabled, any user-mode thread that has been granted a charger device object could call charger_set_prop() with CHARGER_PROP_STATUS_NOTIFICATION or CHARGER_PROP_ONLINE_NOTIFICATION and an arbitrary pointer value. Drivers that implement these properties — drivers/charger/charger_max20335.c, drivers/charger/charger_pf1550.c and drivers/charger/charger_bq2518x.c — store the pointer in device data and later invoke it from their interrupt work handlers, which run in supervisor mode, on any charger state change such as a cable plug/unplug. The result is a control-flow hijack at kernel privilege from an unprivileged thread, defeating the isolation that CONFIG_USERSPACE is meant to provide; the read path additionally disclosed a kernel code address to user mode, and clearing a notifier installed by a supervisor thread let user mode suppress charger notifications. Supervisor-mode callers of charger_set_prop()/charger_get_prop() are unaffected. The fix makes both verifiers reject the two notifier properties outright — including when the supplied callback is NULL, since the notifiers are device state — and adds a BUILD_ASSERT on CHARGER_PROP_COMMON_COUNT so that new properties force a re-review of the union's user-mode safety. It has a CVSS v3.1 base score of 7.8 (HIGH).
How severe is CVE-2026-91007? +
CVE-2026-91007 has a CVSS v3.1 score of 7.8 out of 10, rated HIGH. This is a high-severity vulnerability that should be prioritized for patching. The EPSS score is 0.0011, placing it in the 0th percentile for exploitation probability.
How do I check if I'm vulnerable to CVE-2026-91007? +
You can use Secably's free Website Scanner to check your website for known vulnerabilities. For infrastructure scanning, use the Port Scanner to identify exposed services that may be affected. Check the vendor advisories linked above for specific patch and version information.

Related Vulnerabilities

Don't wait for an exploit

Scan your website for vulnerabilities like CVE-2026-91007 — free, no signup required.

Patch and protect

Block known exploits with a web application firewall while you patch, keep your own devices clean, or test the fix on a fresh server.

Compare VPS prices →

Affiliate links: we may earn a commission, your price stays the same.