CVE-2026-133851

Published Nov 20, 2026 Modified Nov 20, 2026 CWE-362 CWE-862

Description

FlowIntel's alerting module contained an authorization bypass in the alert access control logic. When an alert was linked to a private case, the system relied solely on connector ownership (user or organization) to determine access, without verifying that the requesting user still held valid membership in the associated private case. This meant that a user who was a connector owner of an alert could continue to read alert details, review history, raw payloads, and action comments, and could perform review-status updates or case-creation actions, even after their access to the linked private case had been revoked or they were never a member of that case. Additionally, a time-of-check to time-of-use (TOCTOU) gap existed: after a review-status update or a competing case-creation claim was committed, the response could disclose private case identifiers or review history to a user whose access had been concurrently removed by another session linking the alert to a private case. Impact: - Unauthorized disclosure of private case data (review comments, raw payloads, action history) through alert endpoints. - Unauthorized modification of alert review status and creation of cases from alerts the user should no longer access. - Leakage of a competing case identifier to an unauthorized user during concurrent case-creation races. Affected versions: FlowIntel prior to 4.1.0.

Is your site exposed to CVE-2026-133851?

Run a free security scan — no signup, results in seconds.

Weakness Type (CWE)

CWE-362 CWE-362
CWE-862 Missing Authorization

References

Frequently Asked Questions

What is CVE-2026-133851? +
FlowIntel's alerting module contained an authorization bypass in the alert access control logic. When an alert was linked to a private case, the system relied solely on connector ownership (user or organization) to determine access, without verifying that the requesting user still held valid membership in the associated private case. This meant that a user who was a connector owner of an alert could continue to read alert details, review history, raw payloads, and action comments, and could perform review-status updates or case-creation actions, even after their access to the linked private case had been revoked or they were never a member of that case. Additionally, a time-of-check to time-of-use (TOCTOU) gap existed: after a review-status update or a competing case-creation claim was committed, the response could disclose private case identifiers or review history to a user whose access had been concurrently removed by another session linking the alert to a private case. Impact: - Unauthorized disclosure of private case data (review comments, raw payloads, action history) through alert endpoints. - Unauthorized modification of alert review status and creation of cases from alerts the user should no longer access. - Leakage of a competing case identifier to an unauthorized user during concurrent case-creation races. Affected versions: FlowIntel prior to 4.1.0.
How do I check if I'm vulnerable to CVE-2026-133851? +
You can use Secably's free Website Scanner to check your website for known vulnerabilities. For infrastructure scanning, use the Port Scanner to identify exposed services that may be affected. Check the vendor advisories linked above for specific patch and version information.

Related Vulnerabilities

Don't wait for an exploit

Scan your website for vulnerabilities like CVE-2026-133851 — free, no signup required.

Patch and protect

Block known exploits with a web application firewall while you patch, keep your own devices clean, or test the fix on a fresh server.

Compare VPS prices →

Affiliate links: we may earn a commission, your price stays the same.