CVE-2024-22039

CRITICAL
Published Mar 12, 2024 Modified Nov 21, 2024 CWE-120

Description

A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions < IP8), Cerberus PRO EN Fire Panel FC72x IP6 (All versions < IP6 SR3), Cerberus PRO EN Fire Panel FC72x IP7 (All versions < IP7 SR5), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions < V3.0.6602), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.0.5016), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions < V3.2.6601), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.2.5015), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions < MP8), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions < MP6 SR3), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions < MP7 SR5), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions < V3.0.6602), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.0.5016), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions < V3.2.6601), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.2.5015), Sinteso Mobile (All versions < V3.0.0). The network communication library in affected systems does not validate the length of certain X.509 certificate attributes which might result in a stack-based buffer overflow. This could allow an unauthenticated remote attacker to execute code on the underlying operating system with root privileges.

CVSS v3.1 Score

10.0
CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

Weakness Type (CWE)

CWE-120 CWE-120

Affected Products

Vendor Product
siemens cerberus_pro_en_engineering_tool
siemens cerberus_pro_en_fire_panel_fc72x
siemens cerberus_pro_en_x200_cloud_distribution
siemens cerberus_pro_en_x300_cloud_distribution
siemens sinteso_fs20_en_engineering_tool
siemens sinteso_fs20_en_fire_panel_fc20
siemens sinteso_fs20_en_x200_cloud_distribution
siemens sinteso_fs20_en_x300_cloud_distribution
siemens sinteso_mobile

References

Frequently Asked Questions

What is CVE-2024-22039? +
A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions < IP8), Cerberus PRO EN Fire Panel FC72x IP6 (All versions < IP6 SR3), Cerberus PRO EN Fire Panel FC72x IP7 (All versions < IP7 SR5), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions < V3.0.6602), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.0.5016), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions < V3.2.6601), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.2.5015), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions < MP8), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions < MP6 SR3), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions < MP7 SR5), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions < V3.0.6602), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.0.5016), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions < V3.2.6601), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.2.5015), Sinteso Mobile (All versions < V3.0.0). The network communication library in affected systems does not validate the length of certain X.509 certificate attributes which might result in a stack-based buffer overflow. This could allow an unauthenticated remote attacker to execute code on the underlying operating system with root privileges. It has a CVSS v3.1 base score of 10.0 (CRITICAL).
How severe is CVE-2024-22039? +
CVE-2024-22039 has a CVSS v3.1 score of 10.0 out of 10, rated CRITICAL. This is a critical vulnerability that should be patched immediately.
What products are affected by CVE-2024-22039? +
CVE-2024-22039 affects products from siemens, specifically: cerberus_pro_en_engineering_tool, cerberus_pro_en_fire_panel_fc72x, cerberus_pro_en_x200_cloud_distribution, cerberus_pro_en_x300_cloud_distribution, sinteso_fs20_en_engineering_tool, sinteso_fs20_en_fire_panel_fc20, sinteso_fs20_en_x200_cloud_distribution, sinteso_fs20_en_x300_cloud_distribution, sinteso_mobile. Check the affected products table above for specific version ranges.
How do I check if I'm vulnerable to CVE-2024-22039? +
You can use Secably's free Website Scanner to check your website for known vulnerabilities. For infrastructure scanning, use the Port Scanner to identify exposed services that may be affected. Check the vendor advisories linked above for specific patch and version information.

Related Vulnerabilities

Don't wait for an exploit

Scan your website for vulnerabilities like CVE-2024-22039 — free, no signup required.

Start Free Scan