CVE-2026-64487

Published Jul 25, 2026

Description

In the Linux kernel, the following vulnerability has been resolved: ALSA: caiaq: fix out-of-bounds read in the Traktor Kontrol S4 input parser snd_usb_caiaq_tks4_dispatch() decodes the Traktor Kontrol S4 input stream in fixed 16-byte (TKS4_MSGBLOCK_SIZE) message blocks. On every iteration it advances buf and subtracts the block size while looping on "while (len)". len is urb->actual_length. That value is supplied by the device and is not guaranteed to be a multiple of 16. When a final short block leaves len between 1 and 15, the loop runs once more, reads up to buf[15], and then does "len -= TKS4_MSGBLOCK_SIZE". As len is unsigned this underflows to a huge value. The loop then keeps iterating and walking buf far past the end of the 512-byte ep4_in_buf, reading out of bounds until a bogus block id happens to be hit. Iterate only while a full message block is available. This stops the unsigned underflow and silently drops any trailing partial block, which carries no complete control value anyway. The sibling endpoint-4 parsers are not affected. The Traktor Kontrol X1 and Maschine arms in snd_usb_caiaq_ep4_reply_dispatch() floor urb->actual_length before dispatching.

Is your site exposed to CVE-2026-64487?

Run a free security scan — no signup, results in seconds.

EPSS — Exploit Prediction

0.0022
Probability of exploitation
0.13%
Percentile rank

EPSS estimates the probability that this vulnerability will be exploited in the wild within the next 30 days. A higher score means more likely to be exploited.

References

Frequently Asked Questions

What is CVE-2026-64487? +
In the Linux kernel, the following vulnerability has been resolved: ALSA: caiaq: fix out-of-bounds read in the Traktor Kontrol S4 input parser snd_usb_caiaq_tks4_dispatch() decodes the Traktor Kontrol S4 input stream in fixed 16-byte (TKS4_MSGBLOCK_SIZE) message blocks. On every iteration it advances buf and subtracts the block size while looping on "while (len)". len is urb->actual_length. That value is supplied by the device and is not guaranteed to be a multiple of 16. When a final short block leaves len between 1 and 15, the loop runs once more, reads up to buf[15], and then does "len -= TKS4_MSGBLOCK_SIZE". As len is unsigned this underflows to a huge value. The loop then keeps iterating and walking buf far past the end of the 512-byte ep4_in_buf, reading out of bounds until a bogus block id happens to be hit. Iterate only while a full message block is available. This stops the unsigned underflow and silently drops any trailing partial block, which carries no complete control value anyway. The sibling endpoint-4 parsers are not affected. The Traktor Kontrol X1 and Maschine arms in snd_usb_caiaq_ep4_reply_dispatch() floor urb->actual_length before dispatching.
How do I check if I'm vulnerable to CVE-2026-64487? +
You can use Secably's free Website Scanner to check your website for known vulnerabilities. For infrastructure scanning, use the Port Scanner to identify exposed services that may be affected. Check the vendor advisories linked above for specific patch and version information.

Don't wait for an exploit

Scan your website for vulnerabilities like CVE-2026-64487 — free, no signup required.