In the Linux kernel, the following vulnerability has been resolved: counter: rz-mtu3-cnt: do not use struct rz_mtu3_channel's dev member The counter driver can use HW channels 1 and 2, while the PWM driver can use HW channels 0, 1, 2, 3, 4, 6, 7. The dev member is assigned both by the counter driver and the PWM driver for channels 1 and 2, to their own struct device instance, overwriting the previous value. The sub-drivers race to assign their own struct device pointer to the same struct rz_mtu3_channel's dev member. The dev member of struct rz_mtu3_channel is used by the counter sub-driver for runtime PM. Depending on the probe order of the counter and PWM sub-drivers, the dev member may point to the wrong struct device instance, causing the counter sub-driver to do runtime PM actions on the wrong device. To fix this, use the parent pointer of the counter, which is assigned during probe to the correct struct device, not the struct device pointer inside the shared struct rz_mtu3_channel.

CVSS v3.1 Score

5.5
MEDIUM
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

EPSS — Exploit Prediction

0.0001
Probability of exploitation
0.02%
Percentile rank

EPSS estimates the probability that this vulnerability will be exploited in the wild within the next 30 days. A higher score means more likely to be exploited.

Affected Products

Vendor Product
linux linux_kernel
linux linux_kernel
linux linux_kernel
linux linux_kernel
linux linux_kernel
linux linux_kernel
linux linux_kernel
linux linux_kernel
linux linux_kernel
linux linux_kernel

References

Frequently Asked Questions

What is CVE-2026-31740? +
In the Linux kernel, the following vulnerability has been resolved: counter: rz-mtu3-cnt: do not use struct rz_mtu3_channel's dev member The counter driver can use HW channels 1 and 2, while the PWM driver can use HW channels 0, 1, 2, 3, 4, 6, 7. The dev member is assigned both by the counter driver and the PWM driver for channels 1 and 2, to their own struct device instance, overwriting the previous value. The sub-drivers race to assign their own struct device pointer to the same struct rz_mtu3_channel's dev member. The dev member of struct rz_mtu3_channel is used by the counter sub-driver for runtime PM. Depending on the probe order of the counter and PWM sub-drivers, the dev member may point to the wrong struct device instance, causing the counter sub-driver to do runtime PM actions on the wrong device. To fix this, use the parent pointer of the counter, which is assigned during probe to the correct struct device, not the struct device pointer inside the shared struct rz_mtu3_channel. It has a CVSS v3.1 base score of 5.5 (MEDIUM).
How severe is CVE-2026-31740? +
CVE-2026-31740 has a CVSS v3.1 score of 5.5 out of 10, rated MEDIUM. This is a medium-severity vulnerability that should be remediated as part of regular maintenance. The EPSS score is 0.0001, placing it in the 0th percentile for exploitation probability.
What products are affected by CVE-2026-31740? +
CVE-2026-31740 affects products from linux, specifically: linux_kernel. Check the affected products table above for specific version ranges.
How do I check if I'm vulnerable to CVE-2026-31740? +
You can use Secably's free Website Scanner to check your website for known vulnerabilities. For infrastructure scanning, use the Port Scanner to identify exposed services that may be affected. Check the vendor advisories linked above for specific patch and version information.

Related Vulnerabilities

Don't wait for an exploit

Scan your website for vulnerabilities like CVE-2026-31740 — free, no signup required.

Start Free Scan