CVE-2025-24910

MEDIUM
Published Apr 16, 2025 Modified Apr 15, 2026 CWE-611

Description

Overview   XML documents optionally contain a Document Type Definition (DTD), which, among other features, enables the definition of XML entities. It is possible to define an entity by providing a substitution string in the form of a URI. Once the content of the URI is read, it is fed back into the application that is processing the XML. This application may echo back the data (e.g. in an error message), thereby exposing the file contents. (CWE-611)   Description   Hitachi Vantara Pentaho Business Analytics Server versions before 10.2.0.2, including 9.3.x and 8.3.x, do not correctly protect Pentaho Data Integration MessageSourceCrawler against out-of-band XML External Entity Reference.   Impact   By submitting an XML file that defines an external entity with a file:// URI, an attacker can cause the processing application to read the contents of a local file. Using URIs with other schemes such as http://, the attacker can force the application to make outgoing requests to servers that the attacker cannot reach directly, which can be used to bypass firewall restrictions or hide the source of attacks such as port scanning.

CVSS v3.1 Score

4.9
MEDIUM
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N

Weakness Type (CWE)

CWE-611 CWE-611

References

Frequently Asked Questions

What is CVE-2025-24910? +
Overview   XML documents optionally contain a Document Type Definition (DTD), which, among other features, enables the definition of XML entities. It is possible to define an entity by providing a substitution string in the form of a URI. Once the content of the URI is read, it is fed back into the application that is processing the XML. This application may echo back the data (e.g. in an error message), thereby exposing the file contents. (CWE-611)   Description   Hitachi Vantara Pentaho Business Analytics Server versions before 10.2.0.2, including 9.3.x and 8.3.x, do not correctly protect Pentaho Data Integration MessageSourceCrawler against out-of-band XML External Entity Reference.   Impact   By submitting an XML file that defines an external entity with a file:// URI, an attacker can cause the processing application to read the contents of a local file. Using URIs with other schemes such as http://, the attacker can force the application to make outgoing requests to servers that the attacker cannot reach directly, which can be used to bypass firewall restrictions or hide the source of attacks such as port scanning. It has a CVSS v3.1 base score of 4.9 (MEDIUM).
How severe is CVE-2025-24910? +
CVE-2025-24910 has a CVSS v3.1 score of 4.9 out of 10, rated MEDIUM. This is a medium-severity vulnerability that should be remediated as part of regular maintenance.
How do I check if I'm vulnerable to CVE-2025-24910? +
You can use Secably's free Website Scanner to check your website for known vulnerabilities. For infrastructure scanning, use the Port Scanner to identify exposed services that may be affected. Check the vendor advisories linked above for specific patch and version information.

Related Vulnerabilities

Don't wait for an exploit

Scan your website for vulnerabilities like CVE-2025-24910 — free, no signup required.