CVE-2024-43654
HIGHDescription
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
Is your site exposed to CVE-2024-43654?
Run a free security scan — no signup, results in seconds.
CVSS v3.1 Score
Weakness Type (CWE)
References
Frequently Asked Questions
What is CVE-2024-43654? +
How severe is CVE-2024-43654? +
How do I check if I'm vulnerable to CVE-2024-43654? +
Related Vulnerabilities
Penetration Testing engineers at Amazon discovered a vulnerability where the camera system failed to properly validate input, allowing specially crafted …
An OS Command Injection vulnerability exists in Aterm. If a malicious third person gains administrator access to the product’s web …
3onedata modbus gateway device model GW1101-1D(RS-485)-TB-P (hardware version V2.2.0) allows authenticated users to execute arbitrary shell commands in the context …
WDR201A WiFi Extender (HW V2.1, FW LFMZX28040922V1.02) contains an OS command injection vulnerability in the adm.cgi binary's reboot_time function that …
WDR201A WiFi Extender (HW V2.1, FW LFMZX28040922V1.02) contains an OS command injection vulnerability in the makeRequest.cgi binary that allows unauthenticated …
WDR201A WiFi Extender (HW V2.1, FW LFMZX28040922V1.02) contains an OS command injection vulnerability in the internet.cgi binary that allows unauthenticated …