CVE-2024-25730

CRITICAL
Published Feb 23, 2024 Modified May 5, 2025 CWE-331

Description

Hitron CODA-4582 and CODA-4589 devices have default PSKs that are generated from 5-digit hex values concatenated with a "Hitron" substring, resulting in insufficient entropy (only about one million possibilities).

CVSS v3.1 Score

9.8
CRITICAL
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness Type (CWE)

CWE-331 CWE-331

Affected Products

Vendor Product
hitrontech coda-4582u_firmware
hitrontech coda-4582u
hitrontech coda-4589_firmware
hitrontech coda-4589

References

Frequently Asked Questions

What is CVE-2024-25730? +
Hitron CODA-4582 and CODA-4589 devices have default PSKs that are generated from 5-digit hex values concatenated with a "Hitron" substring, resulting in insufficient entropy (only about one million possibilities). It has a CVSS v3.1 base score of 9.8 (CRITICAL).
How severe is CVE-2024-25730? +
CVE-2024-25730 has a CVSS v3.1 score of 9.8 out of 10, rated CRITICAL. This is a critical vulnerability that should be patched immediately.
What products are affected by CVE-2024-25730? +
CVE-2024-25730 affects products from hitrontech, specifically: coda-4582u, coda-4582u_firmware, coda-4589, coda-4589_firmware. Check the affected products table above for specific version ranges.
How do I check if I'm vulnerable to CVE-2024-25730? +
You can use Secably's free Website Scanner to check your website for known vulnerabilities. For infrastructure scanning, use the Port Scanner to identify exposed services that may be affected. Check the vendor advisories linked above for specific patch and version information.