CVE-2023-38123

HIGH
Published May 3, 2024 Modified Mar 13, 2025 CWE-306

Description

Inductive Automation Ignition OPC UA Quick Client Missing Authentication for Critical Function Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the server configuration. The issue results from the lack of authentication prior to allowing access to password change functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-20540.

Is your site exposed to CVE-2023-38123?

Run a free security scan — no signup, results in seconds.

CVSS v3.1 Score

8.8
HIGH
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Weakness Type (CWE)

CWE-306 Missing Authentication

Affected Products

Vendor Product
inductiveautomation ignition

References

Frequently Asked Questions

What is CVE-2023-38123? +
Inductive Automation Ignition OPC UA Quick Client Missing Authentication for Critical Function Authentication Bypass Vulnerability. This vulnerability allows remote attackers to bypass authentication on affected installations of Inductive Automation Ignition. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the server configuration. The issue results from the lack of authentication prior to allowing access to password change functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-20540. It has a CVSS v3.1 base score of 8.8 (HIGH).
How severe is CVE-2023-38123? +
CVE-2023-38123 has a CVSS v3.1 score of 8.8 out of 10, rated HIGH. This is a high-severity vulnerability that should be prioritized for patching.
What products are affected by CVE-2023-38123? +
CVE-2023-38123 affects products from inductiveautomation, specifically: ignition. Check the affected products table above for specific version ranges.