CVE-2023-32149

HIGH
Published May 3, 2024 Modified Aug 6, 2025 CWE-121

Description

D-Link DIR-2640 prog.cgi Request Handling Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link DIR-2640 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the web management interface, which listens on TCP port 80 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. . Was ZDI-CAN-19546.

Is your site exposed to CVE-2023-32149?

Run a free security scan — no signup, results in seconds.

CVSS v3.1 Score

8.8
HIGH
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness Type (CWE)

CWE-121 CWE-121

Affected Products

Vendor Product
dlink dir-2640_firmware
dlink dir-2640

References

Frequently Asked Questions

What is CVE-2023-32149? +
D-Link DIR-2640 prog.cgi Request Handling Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of D-Link DIR-2640 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the web management interface, which listens on TCP port 80 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. . Was ZDI-CAN-19546. It has a CVSS v3.1 base score of 8.8 (HIGH).
How severe is CVE-2023-32149? +
CVE-2023-32149 has a CVSS v3.1 score of 8.8 out of 10, rated HIGH. This is a high-severity vulnerability that should be prioritized for patching.
What products are affected by CVE-2023-32149? +
CVE-2023-32149 affects products from dlink, specifically: dir-2640, dir-2640_firmware. Check the affected products table above for specific version ranges.
How do I check if I'm vulnerable to CVE-2023-32149? +
You can use Secably's free Website Scanner to check your website for known vulnerabilities. For infrastructure scanning, use the Port Scanner to identify exposed services that may be affected. Check the vendor advisories linked above for specific patch and version information.

Related Vulnerabilities

Don't wait for an exploit

Scan your website for vulnerabilities like CVE-2023-32149 — free, no signup required.