CVE-2022-50545

MEDIUM
Published Oct 7, 2025 Modified Feb 26, 2026 CWE-401

Description

In the Linux kernel, the following vulnerability has been resolved: r6040: Fix kmemleak in probe and remove There is a memory leaks reported by kmemleak: unreferenced object 0xffff888116111000 (size 2048): comm "modprobe", pid 817, jiffies 4294759745 (age 76.502s) hex dump (first 32 bytes): 00 c4 0a 04 81 88 ff ff 08 10 11 16 81 88 ff ff ................ 08 10 11 16 81 88 ff ff 00 00 00 00 00 00 00 00 ................ backtrace: [<ffffffff815bcd82>] kmalloc_trace+0x22/0x60 [<ffffffff827e20ee>] phy_device_create+0x4e/0x90 [<ffffffff827e6072>] get_phy_device+0xd2/0x220 [<ffffffff827e7844>] mdiobus_scan+0xa4/0x2e0 [<ffffffff827e8be2>] __mdiobus_register+0x482/0x8b0 [<ffffffffa01f5d24>] r6040_init_one+0x714/0xd2c [r6040] ... The problem occurs in probe process as follows: r6040_init_one: mdiobus_register mdiobus_scan <- alloc and register phy_device, the reference count of phy_device is 3 r6040_mii_probe phy_connect <- connect to the first phy_device, so the reference count of the first phy_device is 4, others are 3 register_netdev <- fault inject succeeded, goto error handling path // error handling path err_out_mdio_unregister: mdiobus_unregister(lp->mii_bus); err_out_mdio: mdiobus_free(lp->mii_bus); <- the reference count of the first phy_device is 1, it is not released and other phy_devices are released // similarly, the remove process also has the same problem The root cause is traced to the phy_device is not disconnected when removes one r6040 device in r6040_remove_one() or on error handling path after r6040_mii probed successfully. In r6040_mii_probe(), a net ethernet device is connected to the first PHY device of mii_bus, in order to notify the connected driver when the link status changes, which is the default behavior of the PHY infrastructure to handle everything. Therefore the phy_device should be disconnected when removes one r6040 device or on error handling path. Fix it by adding phy_disconnect() when removes one r6040 device or on error handling path after r6040_mii probed successfully.

Is your site exposed to CVE-2022-50545?

Run a free security scan — no signup, results in seconds.

CVSS v3.1 Score

5.5
MEDIUM
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Weakness Type (CWE)

CWE-401 CWE-401

Affected Products

Vendor Product
linux linux_kernel
linux linux_kernel
linux linux_kernel
linux linux_kernel
linux linux_kernel
linux linux_kernel
linux linux_kernel
linux linux_kernel

References

Frequently Asked Questions

What is CVE-2022-50545? +
In the Linux kernel, the following vulnerability has been resolved: r6040: Fix kmemleak in probe and remove There is a memory leaks reported by kmemleak: unreferenced object 0xffff888116111000 (size 2048): comm "modprobe", pid 817, jiffies 4294759745 (age 76.502s) hex dump (first 32 bytes): 00 c4 0a 04 81 88 ff ff 08 10 11 16 81 88 ff ff ................ 08 10 11 16 81 88 ff ff 00 00 00 00 00 00 00 00 ................ backtrace: [<ffffffff815bcd82>] kmalloc_trace+0x22/0x60 [<ffffffff827e20ee>] phy_device_create+0x4e/0x90 [<ffffffff827e6072>] get_phy_device+0xd2/0x220 [<ffffffff827e7844>] mdiobus_scan+0xa4/0x2e0 [<ffffffff827e8be2>] __mdiobus_register+0x482/0x8b0 [<ffffffffa01f5d24>] r6040_init_one+0x714/0xd2c [r6040] ... The problem occurs in probe process as follows: r6040_init_one: mdiobus_register mdiobus_scan <- alloc and register phy_device, the reference count of phy_device is 3 r6040_mii_probe phy_connect <- connect to the first phy_device, so the reference count of the first phy_device is 4, others are 3 register_netdev <- fault inject succeeded, goto error handling path // error handling path err_out_mdio_unregister: mdiobus_unregister(lp->mii_bus); err_out_mdio: mdiobus_free(lp->mii_bus); <- the reference count of the first phy_device is 1, it is not released and other phy_devices are released // similarly, the remove process also has the same problem The root cause is traced to the phy_device is not disconnected when removes one r6040 device in r6040_remove_one() or on error handling path after r6040_mii probed successfully. In r6040_mii_probe(), a net ethernet device is connected to the first PHY device of mii_bus, in order to notify the connected driver when the link status changes, which is the default behavior of the PHY infrastructure to handle everything. Therefore the phy_device should be disconnected when removes one r6040 device or on error handling path. Fix it by adding phy_disconnect() when removes one r6040 device or on error handling path after r6040_mii probed successfully. It has a CVSS v3.1 base score of 5.5 (MEDIUM).
How severe is CVE-2022-50545? +
CVE-2022-50545 has a CVSS v3.1 score of 5.5 out of 10, rated MEDIUM. This is a medium-severity vulnerability that should be remediated as part of regular maintenance.
What products are affected by CVE-2022-50545? +
CVE-2022-50545 affects products from linux, specifically: linux_kernel. Check the affected products table above for specific version ranges.
How do I check if I'm vulnerable to CVE-2022-50545? +
You can use Secably's free Website Scanner to check your website for known vulnerabilities. For infrastructure scanning, use the Port Scanner to identify exposed services that may be affected. Check the vendor advisories linked above for specific patch and version information.

Related Vulnerabilities

Don't wait for an exploit

Scan your website for vulnerabilities like CVE-2022-50545 — free, no signup required.